new version V2017

Zotarolimus eluting stent Drug eluting stent

Medtronic Endeavour - Endeavour      

pdf
TrialStudied treatmentControl treatmentpatientsROBResultNCT

acute myocardial infarction

ZEST AMI (vs PES), 2009zotarolimus eluting stentpaclitaxel eluting stent Risk of bias NegativeNCT00422565
ZEST AMI (vs SES), 2009zotarolimus eluting stentsirolimus eluting stentNegativeNCT00422565

coronary artery disease

ENDEAVOR II, 2006zotarolimus eluting stentbare-metal stentSuggesting
ENDEAVOR III, 2006zotarolimus eluting stentsirolimus eluting stentSuggesting NCT00217256
ZoMaxx I, 2008zotarolimus eluting stentpaclitaxel eluting stent -
ENDEAVOR IV, 2009zotarolimus eluting stentpaclitaxel eluting stent Risk of bias SuggestingNCT00217269
ZEST AMI (vs PES), 2009zotarolimus eluting stentpaclitaxel eluting stent Risk of bias NegativeNCT00422565
ZEST (vs PES), 2009zotarolimus eluting stentpaclitaxel eluting stentSuggestingNCT00418067
ZEST (vs SES), 2009zotarolimus eluting stentsirolimus eluting stent Risk of bias NegativeNCT00418067
ZEST AMI (vs SES), 2009zotarolimus eluting stentsirolimus eluting stentNegativeNCT00422565
RESOLUTE All comers, 2010zotarolimus eluting stenteverolimus eluting stent Risk of bias NegativeNCT00617084.)
SORT-OUT-3, 2010zotarolimus eluting stentsirolimus eluting stent Risk of bias Negative NCT00660478
TWENTE, 2012zotarolimus eluting stenteverolimus eluting stent - NCT01066650
PROTECT, 2012zotarolimus eluting stentsirolimus eluting stent Risk of bias - NCT00476957
ZoMaxx phase 2 ongoing zotarolimus eluting stentpaclitaxel eluting stent - NCT00140101
DIABEDES IV ongoing zotarolimus eluting stentsirolimus eluting stent - NCT00552994
PRISON III, 2007 ongoing zotarolimus eluting stentsirolimus eluting stent - NCT00428454

stable angina

ENDEAVOR II, 2006zotarolimus eluting stentbare-metal stentSuggesting
ENDEAVOR III, 2006zotarolimus eluting stentsirolimus eluting stentSuggesting NCT00217256
ENDEAVOR IV, 2009zotarolimus eluting stentpaclitaxel eluting stent Risk of bias SuggestingNCT00217269
ZEST (vs SES), 2009zotarolimus eluting stentsirolimus eluting stent Risk of bias NegativeNCT00418067
RESOLUTE All comers, 2010zotarolimus eluting stenteverolimus eluting stent Risk of bias NegativeNCT00617084.)
PROTECT, 2012zotarolimus eluting stentsirolimus eluting stent Risk of bias - NCT00476957
ZoMaxx phase 2 ongoing zotarolimus eluting stentpaclitaxel eluting stent - NCT00140101
DIABEDES IV ongoing zotarolimus eluting stentsirolimus eluting stent - NCT00552994
PRISON III, 2007 ongoing zotarolimus eluting stentsirolimus eluting stent - NCT00428454